Differences

This shows you the differences between the selected revision and the current version of the page.

hardware:fan 2007/12/15 21:10 hardware:fan 2017/12/04 19:30 current
Line 1: Line 1:
====== DNS-323 Case Fan: Hardware Version A1 ====== ====== DNS-323 Case Fan: Hardware Version A1 ======
- 
Line 10: Line 9:
===== Variable-Speed Fan Details: ===== ===== Variable-Speed Fan Details: =====
-<box 45% left| Specification >+<box 45% left| Specifications >
^ Model          ^ [[http://www.addausa.com/fans.htm|ADDA AD0405HB-G73]] ^ ^ Model          ^ [[http://www.addausa.com/fans.htm|ADDA AD0405HB-G73]] ^
^ Dimensions    | 40mm x 40mm x 10mm                    | ^ Dimensions    | 40mm x 40mm x 10mm                    |
Line 17: Line 16:
^ Bearing Type  | Ball                                  | ^ Bearing Type  | Ball                                  |
^ Blades        | 7                                    | ^ Blades        | 7                                    |
-^ Wires          | 3 wires (black -?),(red-?),(white-?)  |+^ Wires          | 3 wires (black - GND),(red - +V  [+5 volts?] ),(white - RPM Signal)  |
Motor Protective circuit & third lead wire by IC w/ speed sensor (FG) \\ Motor Protective circuit & third lead wire by IC w/ speed sensor (FG) \\
Source: [[http://www.addausa.com/model_index.pdf|ADDA Model Numbering Scheme]]. Source: [[http://www.addausa.com/model_index.pdf|ADDA Model Numbering Scheme]].
</box> </box>
-<box 45% left | Guessed Specifications >+<box 45% left | Extrapolated Specifications<sup>*</sup> >
^ Speed    | 6000 rpm (revolutions per minute)  | ^ Speed    | 6000 rpm (revolutions per minute)  |
-^ Airflow  | 6.7 or 6.8 cfm                      |+^ Airflow  | 6.7 cfm                      |
^ Pressure  | 0.100 in (inches)                  | ^ Pressure  | 0.100 in (inches)                  |
^ Sound    | 25dB/A                              | ^ Sound    | 25dB/A                              |
^ Weight    | 24 grams                            | ^ Weight    | 24 grams                            |
-^ Power    | ~1.25 Watts (<sup>*</sup> see calculation below) |+^ Power    | 1.25 Watts |
-Source: Guessed values extrapolated from: [[http://www.addausa.com/specifications/up-40.pdf|ADDA Fan Specification Chart]]. Guessed, because the AD0405HB-G73 model is not listed.+Extrapolated from:    \\ 
 +Source: [[http://www.addausa.com/model_index.pdf|ADDA Model Numbering Scheme]]. \\ 
 +Source: [[http://www.addausa.com/specifications/up-40.pdf|ADDA Fan Specification Chart]]. \\ 
 + 
 +* Model Number decoder indicates that the AD0405HB-G72 and AD0405HB-G73 are identical excluding the inclusion of the speed sensor and exclusion of the alarm.
-<sup>*</sup>Power (Watts) = Current(Amperes) x Volts (So, at full-rated standard power) Power = 0.25 Amperes (Current) x 5.0 Volts  ==  1.25 Watts. 
</box> </box>
 +
===== Fan/Cooling Hacks/Mods ===== ===== Fan/Cooling Hacks/Mods =====
-  * Cut out the protective piece of plastic from the back plate, enlarged the opening, added some padding. After that the unit is MUCH more quiet \\ [[http://forum.dsmg600.info/p1226-Yesterday-182055.html#p1226|ondro727's Fan Hack]]+  * A simple [[http://wiki.dns323.info/hardware:fan#fan_control_scripts|fan control script]] that turns off the fan at idle/low temperatures, which otherwise will run constantly by default. 
 + 
 +  * Cut out the protective piece of plastic from the back plate, enlarged the opening, added some padding. After that the unit is MUCH quieter \\ [[http://forum.dsmg600.info/p1226-Yesterday-182055.html#p1226|ondro727's Fan Hack]] 
 + 
 + 
===== Fan/Cooling Forum Posts ===== ===== Fan/Cooling Forum Posts =====
Line 42: Line 50:
  * [[http://forum.dsmg600.info/t203-Disk-spins-every-minutes.html|Disk 1 spins up every 10 minutes]]   * [[http://forum.dsmg600.info/t203-Disk-spins-every-minutes.html|Disk 1 spins up every 10 minutes]]
  * [[http://forum.dsmg600.info/t163-DNS323-disassembly-pictures.html|DNS-323 Disassembly Pictures]]   * [[http://forum.dsmg600.info/t163-DNS323-disassembly-pictures.html|DNS-323 Disassembly Pictures]]
 +  * [[http://forum.dsmg600.info/t2567-Temperature-reading-problem!.html|Temperature control problem]]
 +  * [[http://forum.dsmg600.info/t2800-another-controller.html|Yet another fan controller]] (See also [[http://nas-tweaks.net/CH3SNAS:Tutorials/fancontrol|fan control tutorial at nas-tweaks.net]])
====== Related Software/Commands ====== ====== Related Software/Commands ======
 +
===== fanspeed ===== ===== fanspeed =====
 +Fan speed control for a1 and b1 hardware board:
<code>Query and set the FAN Speed control <code>Query and set the FAN Speed control
Usage: fanspeed [function] Usage: fanspeed [function]
Line 52: Line 64:
w rpm, set fan speed(rpm range:1935~30000) w rpm, set fan speed(rpm range:1935~30000)
g get fan speed</code> g get fan speed</code>
 +Fanspeed control for c1 hardware board (firmware 1.08):
 +<code>fanspeed - query and set the FAN Speed control
 +
 +Usage: fanspeed [function]
 +
 +Functions:
 + h high speed(7000rpm)
 + l low speed(2700rpm)
 + s stop fan
 + g get fan status
 + the below option only support in a1 and b1 hardware board 
 + w rpm, set fan speed(rpm range:0 for stop, 2700~7000)
 +</code>
 +
=== Examples: === === Examples: ===
<code>fanspeed g</code> <code>fanspeed g</code>
Line 61: Line 87:
The fancontrol process appears to restart the fan within a minute if it's running. The fancontrol process appears to restart the fan within a minute if it's running.
<code>fanspeed w 30000</code> <code>fanspeed w 30000</code>
-Not recommended! What happens!? Does anyone have the courage to report? : ) +==== Warnings: ==== 
 + * It has been reported that the fan doesn't spin faster than 6,301 rpm, regardless of the set fan speed. 
 +  * **fanspeed w rpm** does not work with C1 hardware board (see label, bottom of hardware). Please test your hardware since the script below will not work. A script that could work is [[http://forum.dsmg600.info/viewtopic.php?id=5643|here]].
=== Questions: === === Questions: ===
  * What are the best ways to detect if the hard drive is in sleep mode (for use in a script)?   * What are the best ways to detect if the hard drive is in sleep mode (for use in a script)?
Line 68: Line 95:
=== File Location: === === File Location: ===
\sys\crfs\sbin\fanspeed \sys\crfs\sbin\fanspeed
 +
Line 89: Line 117:
  * Does anyone have the source? (reverse engineered code: [[http://www.inreto.de/dns323/utils/]])   * Does anyone have the source? (reverse engineered code: [[http://www.inreto.de/dns323/utils/]])
  * Is documentation essentially right?: [[http://www.google.com/url?sa=t&ct=res&cd=3&url=http%3A%2F%2Fdownload.siliconexpert.com%2Fpdfs%2Fquickdata%2Fphi%2Flm75a_1.pdf&ei=-gfKRbT7GIiGQaLxwKgG&usg=__obkkeDE-YlW6G231wOhnCUIoXxA=&sig2=grVCwxRiRLoR8TNrWK0kuw|Thyst & Tos Information - found by @galf]]   * Is documentation essentially right?: [[http://www.google.com/url?sa=t&ct=res&cd=3&url=http%3A%2F%2Fdownload.siliconexpert.com%2Fpdfs%2Fquickdata%2Fphi%2Flm75a_1.pdf&ei=-gfKRbT7GIiGQaLxwKgG&usg=__obkkeDE-YlW6G231wOhnCUIoXxA=&sig2=grVCwxRiRLoR8TNrWK0kuw|Thyst & Tos Information - found by @galf]]
-  * Does anyone know whether 'temperature g 0' ever reports in Celsius? The wiki's first script seems to think so, but reports so far seem to point to the usage of Fahrenheit as standard.+  * Does anyone know whether 'temperature g 0' ever reports in Celsius? The wiki's first script seems to think so, but reports so far seem to point to the usage of Fahrenheit as standard. --Yes, it reports in Celsius (in Sweden) (It seems to follow the C/F setting in the web-config's Email-alerts)
=== File Location: === === File Location: ===
\sys\crfs\sbin\temperature \sys\crfs\sbin\temperature
Line 104: Line 132:
 +===== Fan Control Scripts: =====
-===== Sample Fan Control Scripts: ===== 
Line 113: Line 141:
-==== Simple steps to install fan control script ==== +==== Simple steps to install the fan control script ==== 
-Thought this can be useful to you as it would to me as a newbie who is technically challenged. This is a feature that should have been set from the factory, as it makes no sense to have the fan running all the time. I'm new at this so please feel free to fix/edit.+I hope this can be useful to you as it would to me as a newbie who is technically challenged.
 +The script (contributed by a collaboration of members here) replaces the factory fan control process,
 +checks for case temperature at set regular intervals and modify fan rotational speed in a positive ratio
 +When drives spin down at idle, the fan will stop as the box temperature lowers to a user defined value.
 +This is a feature that should have been implemented by the D-Link firmware (but isn't), as it makes no sense
 +to have the fan running all the time. It's quite simple to do, and it effectively reduces noise and wear.
 +Please feel free to make corrections.
 +
 +**The Quick and Easy**
 +
 +  * Download {{:hardware:fonz_funplug_0.3_w_fan_control.rar}}.
 +
 +(In script fun_plug variable PATH haven't been set correctly. Correct line is:
 +    PATH=${PATH}:${BINDIR}
 +Somehow device store system variables, so incorrectly set it can cause improper functioning even if you reset device to factory default, or even reburn firmware. In script fan_control.sh we have to add another line:
 +    export PATH
 +right next after PATH declaration line. After these changes HD usage and heat generation of the device dropped dramatically. Another suggestion set temeratures T1 and T2, 97F and 105F accordingly.)
 +  * Open the .rar archive (use [[http://www.rarlab.com/download.htm|WinRAR]]), drop the four files in the archive into your root folder (e.g. /Volume_1/) via ftp or just by simple drag and drop. Reboot immediately.
 +  * After the power light stops blinking, wait one minute. Then telnet into your unit's local IP (default is 192.168.0.32) using a telnet/ssh client (try [[http://www.chiark.greenend.org.uk/~sgtatham/putty/download.html|PuTTY]]) and type
 +
 +
 +    temperature g 0
 +to check your DNS-323's temperature readings.
 +  * If the temperature shows Fahrenheit unit, you are done (you may also type
 +
 +
 +      rm /mnt/HD_a2/ctrl_fanspeed.C
 +in telnet to delete the Celsius version script). If it's below 108F, the fan should have stopped. You can type
 +
 +
 +    fanspeed g
 +to check the fan RPM.
 +  * If the temperature shows in Celsius, in the same telnet screen, type:
 +
 +
 +    mv /mnt/HD_a2/ctrl_fanspeed.C /mnt/HD_a2/ctrl_fanspeed.sh
 +    reboot
 +The last command of course reboots your unit. After which you can recheck the temperature and fan. If it's below 43C, the fan should have stopped, and you are done. __Warning:__ it's imperative that you follow through steps 3, 4, and 5 to verify temperature units, as the fan may never run if you have the wrong numbers feeding the script, possibly resulting in heat damage to hardware. If you encountered problems and must abort, just remove ctrl_fanspeed.sh from your root directory to reset factory fan
 +control settings.
 +
 +**The Nitty Gritty Steps**
  - Get a text editor like [[http://http://sourceforge.net/projects/notepad-plus/|Notepad++]] to save text files in linux format (LF).   - Get a text editor like [[http://http://sourceforge.net/projects/notepad-plus/|Notepad++]] to save text files in linux format (LF).
-  - Create a new text file called fun_plug (no extensions), with the following line:<code bash>/mnt/HD_a2/ctrl_fanspeed.sh</code>save the text file with linux format (LF) to the root directory of your DNS-323 drive (e.g. X:/). Alternatively you can get [[http://www.inreto.de/dns323/fun-plug/|fonz's fun_plug pack]] and add the above line at the end of the included fun_plug file. +  - Create a new text file called [[howto:fun_plug|fun_plug]] (no extensions), with the following line:
-  - create another text file, copy and paste the [["hands-on"]] version of the fan-control script below. Adjust the parameters to your liking (description in comments), though it works fine without any modification. Save the file as ctrl_fanspeed.sh at the root directory (e.g. X:/) of your DNS-323 drive, same location as the fun_plug file. +
-  - Reboot the DNS-323 using D-Link's control page and you are done! +
-You should notice that immediately after booting (when the power light stops flashing) the fan stops. That is if your drive is cooler than the lower limit set in the script (default 108F or 42C). Also make sure your DNS-323 unit reports temperature in F and not C by default (Important! You don't want 108C as lower limit!), something you can do with simple telnet commands.+
-Is it safe to assume US models are all reporting in Fahrenheit?+      /mnt/HD_a2/ctrl_fanspeed.sh 
 + 
 +save the text file with linux format (LF) to the root directory of your DNS-323 drive 
 +(e.g. /Volume_1/ or just drag and drop into your mapped drive). \\ Alternatively, you can get  
 +[[http://www.inreto.de/dns323/fun-plug/|fonz's fun_plug pack]] (which adds telnet feature among other things) and add the above line 
 +at the end of the included fun_plug file (don't drop it into /mnt/HD_a2/fun_plug.d/start/ directory as it's a loop that stops 
 +any script that follows it from loading), or use the folowing lines at the end of the fun_plug file:<code bash># run fanspeed 
 +controller script 
 + 
 +FAN_SPEED=/mnt/HD_a2/ctrl_fanspeed.sh 
 +if [ -x $FAN_SPEED ]; then 
 + echo "* Running $FAN_SPEED ..." 
 + $FAN_SPEED & 
 + echo "* OK" 
 +fi 
 + 
 +  - Create another text file, copy and paste the "general use" version of the fan-control script below. Adjust the parameters 
 +to your liking (description in comments), though it works fine without any modification (assuming your unit reports temperature 
 +in Fahrenheit). Save the file as ctrl_fanspeed.sh at the root directory (e.g. /Volume_1/) of your DNS-323 drive, same location 
 +as the fun_plug file. 
 +  - Reboot the DNS-323 using D-Link's control page and you are done!
 +You should notice that immediately after booting (when the power light stops flashing) the fan stops. That is if your drive is
 +cooler than the lower limit set in the script (default 108F or 42C), which will eventually be the case after HD spins down at idle,
 +or if you boot the unit cold.
 +Also make sure your DNS-323 unit reports temperature readings that matches the temperature unit in the script, which is
 +in Fahrenheit (Important! You don't want 108C as lower limit!). You can do this with a simple [[howto:telnet|telnet]]
 +command ''temperature g 0''. You will need to convert the temperature parameters in the script if your DNS-323 returns
 +temperature readings in Celsius.
 +Is it safe to assume all US models are reporting in Fahrenheit? Mine does.
-===== ctrl_fanspeed.sh =====+==== ctrl_fanspeed.sh ====
-This simple script changes the speed of the fan based on the reported temperature. Note that this script only works if the temperatures are reported in Celsius! By running temperature g 0 you can see what temperature-unit your box uses. The script will be update with a more general solution asap. The parameter-values are only given as examples. Make sure that the temperature of your box remain reasonable under different loads. +This sample script changes the speed of the fan based on the reported temperature. Note that this script is written with temperature reference in Celsius. By running ''temperature g 0'' via [[http://wiki.dns323.info/howto:telnet|telnet]] you can see what temperature-unit your box uses. The parameter-values are only given as examples.
The script can be run in the background where it will remain active and periodically update the speed of the fan. To avoid clashes with the fancontrol process, it is probably best to kill it before this script is run. The script can be run in the background where it will remain active and periodically update the speed of the fan. To avoid clashes with the fancontrol process, it is probably best to kill it before this script is run.
Line 157: Line 250:
</code> </code>
-==== A polished ctrl_fanspeed.sh example ==== 
-This script automatically kills the factory fancontrol process and loads the script into RAM disk, so to avoid periodic disk spin-ups. You can also comment-out (adding # in front of) the 3 lines following ''# Create a logfile on the RAM-disk'' as well as every line that starts with ''echo'' to turn off logging. 
-A more "hands on" example of a script to control fanspeeds. As with the one above, make sure that the parameters of the temperature and fanspeeds correctly corresponds to your box. Please read through the thread [[http://forum.dsmg600.info/t185-does-time.html|Fan does run all the time]] before you install this script.+=== A general use ctrl_fanspeed.sh script === 
 +This script automatically kills the factory fancontrol process and loads the script into RAM disk, so to avoid periodic disk spin-ups as the script runs continuously. You can also comment-out (adding # in front of) the 3 lines following ''# Create a logfile on the RAM-disk'' as well as every line that starts with ''echo'' to turn off logging. This script is written with temperature reported in Fahrenheit. You will have to convert the T1/T2 parameter values if your unit reports in Celsius. 
 + 
 +It's a more polished example of a script to control fan speeds. Please read through the thread [[http://forum.dsmg600.info/t185-does-time.html|Fan does run all the time]] before you install this script.
<code bash> <code bash>
Line 172: Line 266:
# edit it to work. # edit it to work.
# Additional changes by gartylad. # Additional changes by gartylad.
 +# Uriel : corrected zero fanspeed when T exceeded T2
 +#        minor code updates
# Set the path to use RAM-disk instead of harddrive, to # Set the path to use RAM-disk instead of harddrive, to
Line 183: Line 279:
mkdir -p ${LOGDIR} mkdir -p ${LOGDIR}
-# Kill the old fan controller. +echo "Installing fan_ctrl.sh" >${FANLOGFILE} 
-kill -9 `pidof fancontrol` + 
-echo "Fancontrol killed. Installing fan_ctrl.sh" >${FANLOGFILE}+# Kill the old fancontrol process if required 
 +OLDPID=`pidof fancontrol` 
 +if [ "$OLDPID" != "" ] 
 +then 
 +  kill -9 $OLDPID 
 +  echo "killed old fancontrol process ($OLPID)"; >;>${FANLOGFILE} 
 +fi 
 + 
# With temps between T1 and T2, the script automatically # With temps between T1 and T2, the script automatically
-# lowers/raises the fanspeed between RPM1 and RPM2. This+# lowers/raises the fan speed between RPM1 and RPM2. This
# it does every update_interval seconds. # it does every update_interval seconds.
update_interval=60 update_interval=60
Line 195: Line 299:
RPM1=2300 RPM1=2300
RPM2=4500 RPM2=4500
 +RPM3=15000
 +DRPM_DT=`expr \( $RPM2 - $RPM1 \) / \( $T2 - $T1 \)`
 +
while [ 1 ] while [ 1 ]
Line 200: Line 307:
  T=`temperature g 0`   T=`temperature g 0`
  T=${T##*=}   T=${T##*=}
 +
  # Check if temperature has fallen below T1 value   # Check if temperature has fallen below T1 value
  if [ $T -lt $T1 ]; then   if [ $T -lt $T1 ]; then
- # Temp below T1 fan stops +    # Temp below T1 fan stops 
- CALCTEMP=`expr 0` +   NEWRPM=0 
 +  elif [ $T -gt $T2 ]; then 
 +    # Temp greater than T2 requires emergency action 
 +    NEWRPM=$RPM3
  else   else
- # Temp above T1 fan starts +    # Compute new RPMs if in T1..T2 range 
- CALCTEMP=`expr \( \( $T2 \< $T \) \* $RPM2 \) \| \( \( $RPM1 + \( $RPM2 - $RPM1 \) \* \( $T - $T1 \) \/ \( $T2 - $T1 \) \) \& \( $T \>= $T1 \) \)`+   NEWRPM=`expr $RPM1 + \( \( $T - $T1 \) \* $DRPM_DT \)`
  fi   fi
 +
 +
  CONVFTOC=`expr \( \( $T - 32 \) \* 10 + 9 \) \/ 18`   CONVFTOC=`expr \( \( $T - 32 \) \* 10 + 9 \) \/ 18`
-  newRPM=${CALCTEMP} +  fanspeed w $NEWRPM  
-  fanspeed w $newRPM  +  echo `date`" ::CURRENT::" $T"F" ${CONVFTOC}"C -- fanspeed:" $NEWRPM "(written to "${FANLOGFILE}")." >>${FANLOGFILE}
-  echo `date`" ::CURRENT::" $T"F" ${CONVFTOC}"C -- fanspeed:" $newRPM "(written to "${FANLOGFILE}")." >>${FANLOGFILE}+
  # wait for next cycle   # wait for next cycle
  sleep $update_interval   sleep $update_interval
done done
 +</code>
 +
 +If you are using ffp, you may save the script above as /ffp/bin/fan_ctrl.sh and create an additional script /ffp/start/fan.sh to auto-start your fan control script when the ffp initializes.
 +
 +<code bash>
 +#!/ffp/bin/sh
 +
 +# PROVIDE: fan_ctrl.sh
 +# REQUIRE: LOGIN
 +
 +. /ffp/etc/ffp.subr
 +
 +name="fan_ctrl.sh"
 +command="/ffp/bin/$name"
 +sshd_flags=
 +
 +start_cmd="fan_ctrl_start"
 +
 +fan_ctrl_start()
 +{
 +        proc_start_bg $command
 +}
 +
 +run_rc_command "$1"
</code> </code>