-euyoung你好 我是香港的站友 很喜歡你的部落格 相片拍得很好 相機的介紹也很有深度啊 看完你的文章 我忍不住買入 GX200 呢 我也有交換明信片的喜好 會把自己拍的相片印成明信片 我用過 moo.com  印出來的明信片質素不錯 就是比較貴 不知你是在哪裡印明信片的呢 看來很不錯的說 如果喜歡交交新朋友 和不認識的人換明信片 可以試試 Postcrossing.com  這裡有沒有 postcrosser 站友 +====== DNS-323 Case Fan: Hardware Version A1 ====== 
 + 
 + 
 +===== Fan Photos - In Context: ===== 
 +<box 65%|[[http://duplo.org/~conny/dns-323/|Disassembly pictures]]>{{:8.jpg?w=120&h=89|1 - cover off/best/3 wires}} {{:3.jpg?w=120&h=90|2 - exterior}} {{:hardware:7.jpg?w=120&h=90|3 - interior, in case}}{{:hardware:10.jpg?w=120&h=90|4 - interior, out of case}}</box> 
 + 
 + 
 + 
 + 
 +===== Variable-Speed Fan Details: ===== 
 +<box 45% left| Specifications > 
 +^ Model          ^ [[http://www.addausa.com/fans.htm|ADDA AD0405HB-G73]] ^  
 +^ Dimensions    | 40mm x 40mm x 10mm                    | 
 +^ Voltage        | 5 volts dc                            | 
 +^ Current        | 0.25 amperes                          | 
 +^ Bearing Type  | Ball                                  | 
 +^ Blades        | 7                                    | 
 +^ Wires          | 3 wires (black - GND),(red - +V [+5 volts?] ),(white - RPM Signal)  | 
 +Motor Protective circuit & third lead wire by IC w/ speed sensor (FG) \\  
 +Source: [[http://www.addausa.com/model_index.pdf|ADDA Model Numbering Scheme]]. 
 +</box> 
 +<box 45% left | Extrapolated Specifications<sup>*</sup> > 
 +^ Speed    | 6000 rpm (revolutions per minute)  | 
 +^ Airflow  | 6.7 cfm                      | 
 +^ Pressure | 0.100 in (inches)                  | 
 +^ Sound    | 25dB/A                              | 
 +^ Weight    | 24 grams                            | 
 +^ Power    | 1.25 Watts | 
 + 
 +Extrapolated from:    \\ 
 +Source: [[http://www.addausa.com/model_index.pdf|ADDA Model Numbering Scheme]]. \\ 
 +Source: [[http://www.addausa.com/specifications/up-40.pdf|ADDA Fan Specification Chart]]. \\ 
 + 
 +* Model Number decoder indicates that the AD0405HB-G72 and AD0405HB-G73 are identical excluding the inclusion of the speed sensor and exclusion of the alarm. 
 + 
 +</box> 
 + 
 + 
 +===== Fan/Cooling Hacks/Mods ===== 
 +  * A simple [[http://wiki.dns323.info/hardware:fan#fan_control_scripts|fan control script]] that turns off the fan at idle/low temperatures, which otherwise will run constantly by default. 
 + 
 +  * Cut out the protective piece of plastic from the back plate, enlarged the opening, added some padding. After that the unit is MUCH quieter \\ [[http://forum.dsmg600.info/p1226-Yesterday-182055.html#p1226|ondro727's Fan Hack]] 
 + 
 + 
 + 
 + 
 +===== Fan/Cooling Forum Posts ===== 
 +  * [[http://forum.dsmg600.info/t185-does-time.html|Fan does run all the time]] 
 +  * [[http://forum.dsmg600.info/p945-20070122-132130.html#p945 | DNS-323]] 
 +  * [[http://forum.dsmg600.info/t203-Disk-spins-every-minutes.html|Disk 1 spins up every 10 minutes]] 
 +  * [[http://forum.dsmg600.info/t163-DNS323-disassembly-pictures.html|DNS-323 Disassembly Pictures]] 
 +  * [[http://forum.dsmg600.info/t2567-Temperature-reading-problem!.html|Temperature control problem]] 
 +  * [[http://forum.dsmg600.info/t2800-another-controller.html|Yet another fan controller]] (See also [[http://nas-tweaks.net/CH3SNAS:Tutorials/fancontrol|fan control tutorial at nas-tweaks.net]]) 
 + 
 +====== Related Software/Commands ====== 
 + 
 +===== fanspeed ===== 
 +Fan speed control for a1 and b1 hardware board: 
 +<code>Query and set the FAN Speed control 
 +Usage: fanspeed [function] 
 + 
 +Functions: 
 +h show this help 
 +w rpm, set fan speed(rpm range:1935~30000) 
 +g get fan speed</code> 
 +Fanspeed control for c1 hardware board (firmware 1.08): 
 +<code>fanspeed - query and set the FAN Speed control 
 + 
 +Usage: fanspeed [function] 
 + 
 +Functions: 
 + h high speed(7000rpm) 
 + l low speed(2700rpm)  
 + s stop fan  
 + g get fan status 
 + the below option only support in a1 and b1 hardware board   
 + w rpm, set fan speed(rpm range:0 for stop, 2700~7000)  
 +</code> 
 + 
 +=== Examples: === 
 +<code>fanspeed g</code> 
 +Returns the fan's current speed in rpm (revolutions per minute). 
 +<code>fanspeed w 2500</code> 
 +Sets the fan's speed to 2,500 rpm. 
 +<code>fanspeed w 0</code> 
 +Sets the fan's speed to 0 rpm (Stops the fan).  
 +The fancontrol process appears to restart the fan within a minute if it's running. 
 +<code>fanspeed w 30000</code> 
 +==== Warnings: ==== 
 +  * It has been reported that the fan doesn't spin faster than 6,301 rpm, regardless of the set fan speed. 
 +  * **fanspeed w rpm** does not work with C1 hardware board (see label, bottom of hardware). Please test your hardware since the script below will not work. A script that could work is [[http://forum.dsmg600.info/viewtopic.php?id=5643|here]]. 
 +=== Questions: === 
 +  * What are the best ways to detect if the hard drive is in sleep mode (for use in a script)?  
 +  * Does anyone have the source? 
 +=== File Location: === 
 +\sys\crfs\sbin\fanspeed 
 + 
 + 
 + 
 + 
 +===== temperature ===== 
 +<code>Query and set the temperature sensor 
 +Usage: temperature [function] 
 + 
 +Functions: 
 +h - show this help 
 +w [1,2] degree - set temperature degree in register 1:Thyst 2:Tos 
 +g [0~2] - get temperature in register 0:temperature 1:Thyst 2:Tos</code> 
 +== Examples: == 
 +<code>temperature g 0</code> 
 +Returns the current temperature.  Anybody know where the temperature probe is located? 
 +<code>temperature g 1</code> 
 +Returns the [[wp>Hysteresis#Electronics|hysteresis]] Thyst register value/limit. Default setting = 75 degrees C / 167 degrees F. 
 +<code>temperature g 2</code> 
 +Returns the Overtemp shutdown Tos register value/threshold. Default setting = 80 degrees C / 176 degrees F. 
 +=== Questions: === 
 +  * Does anyone have the source? (reverse engineered code: [[http://www.inreto.de/dns323/utils/]]) 
 +  * Is documentation essentially right?: [[http://www.google.com/url?sa=t&ct=res&cd=3&url=http%3A%2F%2Fdownload.siliconexpert.com%2Fpdfs%2Fquickdata%2Fphi%2Flm75a_1.pdf&ei=-gfKRbT7GIiGQaLxwKgG&usg=__obkkeDE-YlW6G231wOhnCUIoXxA=&sig2=grVCwxRiRLoR8TNrWK0kuw|Thyst & Tos Information - found by @galf]] 
 +  * Does anyone know whether 'temperature g 0' ever reports in Celsius? The wiki's first script seems to think so, but reports so far seem to point to the usage of Fahrenheit as standard. --Yes, it reports in Celsius (in Sweden) (It seems to follow the C/F setting in the web-config's Email-alerts) 
 +=== File Location: === 
 +\sys\crfs\sbin\temperature 
 + 
 + 
 +===== fancontrol ===== 
 +Appears to be a daemon, running all the time by default. 
 +=== Questions: === 
 +  * It appears to query the temperature and set appropriate fan speeds approximately every 60 seconds. 
 +  * Does anyone know what it does, exactly? 
 +  * Does anyone have the source? (reverse engineered code: [[http://www.inreto.de/dns323/utils/]]) 
 +=== File Location: === 
 +\sys\crfs\sbin\fancontrol 
 + 
 + 
 +===== Fan Control Scripts: ===== 
 + 
 + 
 + 
 + 
 + 
 + 
 + 
 + 
 +==== Simple steps to install the fan control script ==== 
 +I hope this can be useful to you as it would to me as a newbie who is technically challenged. 
 + 
 +The script (contributed by a collaboration of members here) replaces the factory fan control process, 
 +checks for case temperature at set regular intervals and modify fan rotational speed in a positive ratio 
 +When drives spin down at idle, the fan will stop as the box temperature lowers to a user defined value. 
 +This is a feature that should have been implemented by the D-Link firmware (but isn't), as it makes no sense 
 +to have the fan running all the time. It's quite simple to do, and it effectively reduces noise and wear. 
 +Please feel free to make corrections. 
 + 
 +**The Quick and Easy** 
 + 
 +  * Download {{:hardware:fonz_funplug_0.3_w_fan_control.rar}}.  
 + 
 +(In script fun_plug variable PATH haven't been set correctly. Correct line is: 
 +    PATH=${PATH}:${BINDIR}  
 +Somehow device store system variables, so incorrectly set it can cause improper functioning even if you reset device to factory default, or even reburn firmware. In script fan_control.sh we have to add another line: 
 +    export PATH 
 +right next after PATH declaration line. After these changes HD usage and heat generation of the device dropped dramatically. Another suggestion set temeratures T1 and T2, 97F and 105F accordingly.) 
 +  * Open the .rar archive (use [[http://www.rarlab.com/download.htm|WinRAR]]), drop the four files in the archive into your root folder (e.g. /Volume_1/) via ftp or just by simple drag and drop. Reboot immediately. 
 +  * After the power light stops blinking, wait one minute. Then telnet into your unit's local IP (default is 192.168.0.32) using a telnet/ssh client (try [[http://www.chiark.greenend.org.uk/~sgtatham/putty/download.html|PuTTY]]) and type 
 + 
 + 
 +    temperature g 0 
 +to check your DNS-323's temperature readings. 
 +  * If the temperature shows Fahrenheit unit, you are done (you may also type 
 + 
 + 
 +      rm /mnt/HD_a2/ctrl_fanspeed.C 
 +in telnet to delete the Celsius version script). If it's below 108F, the fan should have stopped. You can type 
 + 
 + 
 +    fanspeed g 
 +to check the fan RPM. 
 +  * If the temperature shows in Celsius, in the same telnet screen, type: 
 + 
 + 
 +    mv /mnt/HD_a2/ctrl_fanspeed.C /mnt/HD_a2/ctrl_fanspeed.sh 
 +    reboot 
 +The last command of course reboots your unit. After which you can recheck the temperature and fan. If it's below 43C, the fan should have stopped, and you are done. __Warning:__ it's imperative that you follow through steps 3, 4, and 5 to verify temperature units, as the fan may never run if you have the wrong numbers feeding the script, possibly resulting in heat damage to hardware. If you encountered problems and must abort, just remove ctrl_fanspeed.sh from your root directory to reset factory fan 
 +control settings. 
 + 
 +**The Nitty Gritty Steps** 
 +  - Get a text editor like [[http://http://sourceforge.net/projects/notepad-plus/|Notepad++]] to save text files in linux format (LF). 
 +  - Create a new text file called [[howto:fun_plug|fun_plug]] (no extensions), with the following line: 
 + 
 +      /mnt/HD_a2/ctrl_fanspeed.sh 
 + 
 +save the text file with linux format (LF) to the root directory of your DNS-323 drive 
 +(e.g. /Volume_1/ or just drag and drop into your mapped drive). \\ Alternatively, you can get  
 +[[http://www.inreto.de/dns323/fun-plug/|fonz's fun_plug pack]] (which adds telnet feature among other things) and add the above line 
 +at the end of the included fun_plug file (don't drop it into /mnt/HD_a2/fun_plug.d/start/ directory as it's a loop that stops 
 +any script that follows it from loading), or use the folowing lines at the end of the fun_plug file:<code bash># run fanspeed 
 +controller script 
 + 
 +FAN_SPEED=/mnt/HD_a2/ctrl_fanspeed.sh 
 +if [ -x $FAN_SPEED ]; then 
 + echo "* Running $FAN_SPEED ..." 
 + $FAN_SPEED & 
 + echo "* OK" 
 +fi 
 + 
 +  - Create another text file, copy and paste the "general use" version of the fan-control script below. Adjust the parameters 
 +to your liking (description in comments), though it works fine without any modification (assuming your unit reports temperature 
 +in Fahrenheit). Save the file as ctrl_fanspeed.sh at the root directory (e.g. /Volume_1/) of your DNS-323 drive, same location 
 +as the fun_plug file. 
 +  - Reboot the DNS-323 using D-Link's control page and you are done! 
 + 
 +You should notice that immediately after booting (when the power light stops flashing) the fan stops. That is if your drive is 
 +cooler than the lower limit set in the script (default 108F or 42C), which will eventually be the case after HD spins down at idle, 
 +or if you boot the unit cold. 
 + 
 +Also make sure your DNS-323 unit reports temperature readings that matches the temperature unit in the script, which is 
 +in Fahrenheit (Important! You don't want 108C as lower limit!). You can do this with a simple [[howto:telnet|telnet]] 
 +command ''temperature g 0''. You will need to convert the temperature parameters in the script if your DNS-323 returns 
 +temperature readings in Celsius. 
 + 
 +Is it safe to assume all US models are reporting in Fahrenheit? Mine does. 
 + 
 +==== ctrl_fanspeed.sh ==== 
 + 
 +This sample script changes the speed of the fan based on the reported temperature. Note that this script is written with temperature reference in Celsius. By running ''temperature g 0'' via [[http://wiki.dns323.info/howto:telnet|telnet]] you can see what temperature-unit your box uses. The parameter-values are only given as examples. 
 + 
 +The script can be run in the background where it will remain active and periodically update the speed of the fan. To avoid clashes with the fancontrol process, it is probably best to kill it before this script is run.  
 + 
 +<code bash> 
 +#!/bin/sh 
 +
 +# ctrl_fanspeed.sh  Script for controlling the speed of the fan on an DNS-323 
 +
 +#At temperatures below T1 it sets the fan to RPM1, while at temperatures above T2 it sets it to RPM2.  
 +#At temperatures between T1 and T2 it linearly interpolates the speed of the fan from RPM1 at T1, to RPM2 at T2.  
 +#The temperature is checked every INTERVAL seconds. 
 + 
 +INTERVAL=15 
 +T1=40 
 +T2=60 
 +RPM1=1000 
 +RPM2=6000 
 + 
 +while [ 1 ] 
 +do 
 +  T=`temperature g 0|sed -n ' s/<temperaturertc>: get temperature =//p'` 
 +  NEW_RPM=`expr  \( $T \> $T2 \) \* $RPM2 \| \( $T \< $T1 \) \* $RPM1  \| $RPM1 + \( $RPM2 - $RPM1 \) \* \( $T - $T1 \) \/ \( $T2 - $T1 \)`  
 +  fanspeed w $NEW_RPM  
 +  sleep $INTERVAL 
 +done 
 +</code> 
 + 
 + 
 +=== A general use ctrl_fanspeed.sh script === 
 +This script automatically kills the factory fancontrol process and loads the script into RAM disk, so to avoid periodic disk spin-ups as the script runs continuously. You can also comment-out (adding # in front of) the 3 lines following ''# Create a logfile on the RAM-disk'' as well as every line that starts with ''echo'' to turn off logging. This script is written with temperature reported in Fahrenheit. You will have to convert the T1/T2 parameter values if your unit reports in Celsius. 
 + 
 +It's a more polished example of a script to control fan speeds. Please read through the thread [[http://forum.dsmg600.info/t185-does-time.html|Fan does run all the time]] before you install this script. 
 + 
 +<code bash> 
 +#!/bin/sh 
 +
 +# This script was created at http://wiki.dns323.info by FIB, 
 +# it has been slightly modified by leper (with help from 
 +# fonz). It sets the fanspeed of the device depending on  
 +# the temperature, which is measured in Fahrenheit. If  
 +# your box measures temperature in Celsius, you need to  
 +# edit it to work. 
 +# Additional changes by gartylad. 
 +# Uriel : corrected zero fanspeed when T exceeded T2 
 +#        minor code updates 
 + 
 +# Set the path to use RAM-disk instead of harddrive, to  
 +# execute from. This is done so that the disks will go 
 +# into sleep mode, while the script is running. 
 +PATH=/usr/bin:/bin:/usr/sbin:/sbin 
 + 
 +# Create a logfile on the RAM-disk. 
 +LOGDIR=/log 
 +FANLOGFILE=${LOGDIR}/fan_ctrl.log 
 +mkdir -p ${LOGDIR} 
 + 
 +echo "Installing fan_ctrl.sh" >${FANLOGFILE} 
 + 
 +# Kill the old fancontrol process if required 
 +OLDPID=`pidof fancontrol` 
 +if [ "$OLDPID" != "" ] 
 +then 
 +  kill -9 $OLDPID 
 +  echo "killed old fancontrol process ($OLPID)" >>${FANLOGFILE} 
 +fi 
 + 
 + 
 + 
 +# With temps between T1 and T2, the script automatically 
 +# lowers/raises the fan speed between RPM1 and RPM2. This 
 +# it does every update_interval seconds. 
 +update_interval=60 
 +T1=108 
 +T2=140 
 +RPM1=2300 
 +RPM2=4500 
 +RPM3=15000 
 +DRPM_DT=`expr \( $RPM2 - $RPM1 \) / \( $T2 - $T1 \)` 
 + 
 + 
 +while [ 1 ] 
 +do 
 +  T=`temperature g 0` 
 +  T=${T##*=} 
 + 
 +  # Check if temperature has fallen below T1 value 
 +  if [ $T -lt $T1 ]; then 
 +    # Temp below T1 fan stops 
 +    NEWRPM=0 
 +  elif [ $T -gt $T2 ]; then 
 +    # Temp greater than T2 requires emergency action 
 +    NEWRPM=$RPM3 
 +  else 
 +    # Compute new RPMs if in T1..T2 range 
 +    NEWRPM=`expr $RPM1 + \( \( $T - $T1 \) \* $DRPM_DT \)` 
 +  fi 
 + 
 + 
 +  CONVFTOC=`expr \( \( $T - 32 \) \* 10 + 9 \) \/ 18` 
 +  fanspeed w $NEWRPM   
 +  echo `date`" ::CURRENT::" $T"F" ${CONVFTOC}"C -- fanspeed:" $NEWRPM "(written to "${FANLOGFILE}")." >>${FANLOGFILE} 
 +  # wait for next cycle 
 +  sleep $update_interval 
 +done 
 +</code> 
 + 
 +If you are using ffp, you may save the script above as /ffp/bin/fan_ctrl.sh and create an additional script /ffp/start/fan.sh to auto-start your fan control script when the ffp initializes. 
 + 
 +<code bash> 
 +#!/ffp/bin/sh 
 + 
 +# PROVIDE: fan_ctrl.sh 
 +# REQUIRE: LOGIN 
 + 
 +. /ffp/etc/ffp.subr 
 + 
 +name="fan_ctrl.sh" 
 +command="/ffp/bin/$name" 
 +sshd_flags= 
 + 
 +start_cmd="fan_ctrl_start" 
 + 
 +fan_ctrl_start() 
 +
 +        proc_start_bg $command 
 +
 + 
 +run_rc_command "$1" 
 +</code> 
 + 
 +===== Other Reference:===== 
 +  * [[http://www.addausa.com/curves/40x10.jpg|ADDA 40mm Fan Performance Curves]] 
 +  * [[http://www.addausa.com/options/options-index.html|Options (??not sure??)]]